Kabel Kabel yang Digunakan Ditegangan Rendah(TR),Menengah(TM) dan Tinggi(TT)

By : Naldo hatake 1 Comment

Kabel Kabel yang Digunakan Ditegangan Rendah(TR),Menengah(TM) dan Tinggi(TT)



Tegangan Tinggi

High Voltage ConductorAAC 
AAC
AAAC
AAAC/s with Grease
ACSR
T-ACSR
Rectangular Wire
BCCH, BCCsoft

Tegangan Menengah

Medium Voltage Tembaga & Alumunium Non  Armour
N2XSY = Cu/XLPE/CTS/PVC 3,6/6 kV, 6/10 kV, 12/20 kV, 18/30kV – Single Core & 3 Core
N2XCY = Cu/XLPE/CWS/PVC 3,6/6 kV, 6/10 kV, 12/20 kV, 18/30kV – Single Core & 3 Core
NA2XSY = AL/XLPE/CTS/PVC 3,6/6 kV, 6/10 kV, 12/20 kV, 18/30kV – Single Core & 3 Core
NA2XCY = AL/XLPE/CWS/PVC 3,6/6 kV, 6/10 kV, 12/20 kV, 18/30kV – Single Core & 3 Core

Medium Voltage Tembaga  Armour
N2XSEBY              = Cu/XLPE/CTS/DSTA/PVC 3,6/6 kV, 6/10 kV, 12/20 kV, 18/30kV – 3 Core
N2XSEYBY            = Cu/XLPE/CWS/DSTA/PVC 3,6/6 kV, 6/10 kV, 12/20 kV, 18/30kV – 3 Core
N2XSEFGBY        = Cu/XLPE/CTS/AWA/PVC 3,6/6 kV, 6/10 kV, 12/20 kV, 18/30kV – 3 Core
N2XSEYFGBY      = Cu/XLPE/CWS/AWA/PVC 3,6/6 kV, 6/10 kV, 12/20 kV, 18/30kV – 3 Core
N2XSERGBY        = Cu/XLPE/CTS/AWA/PVC 3,6/6 kV, 6/10 kV, 12/20 kV, 18/30kV – Single Core
                                = Cu/XLPE/CTS/SWA/PVC 3,6/6 kV, 6/10 kV, 12/20 kV, 18/30kV – 3 Core
N2XSEYRGBY      = Cu/XLPE/CWS/AWA/PVC 3,6/6 kV, 6/10 kV, 12/20 kV, 18/30kV – Single Core
                                = Cu/XLPE/CWS/SWA/PVC 3,6/6 kV, 6/10 kV, 12/20 kV, 18/30kV – 3 Core

Medium Voltage Alumunium Armour
NA2XSEBY           = AL/XLPE/CTS/DSTA/PVC 3,6/6 kV, 6/10 kV, 12/20 kV, 18/30kV – 3 Core
NA2XSEYBY         = AL/XLPE/CWS/DSTA/PVC 3,6/6 kV, 6/10 kV, 12/20 kV, 18/30kV – 3 Core
NA2XSEFGBY     = AL/XLPE/CTS/AWA/PVC 3,6/6 kV, 6/10 kV, 12/20 kV, 18/30kV – 3 Core
NA2XSEYFGBY   = AL/XLPE/CWS/AWA/PVC 3,6/6 kV, 6/10 kV, 12/20 kV, 18/30kV – 3 Core
NA2XSERGBY     = AL/XLPE/CTS/AWA/PVC 3,6/6 kV, 6/10 kV, 12/20 kV, 18/30kV – Single Core
                                = AL/XLPE/CTS/SWA/PVC 3,6/6 kV, 6/10 kV, 12/20 kV, 18/30kV – 3 Core
NA2XSEYRGBY   = AL/XLPE/CWS/AWA/PVC 3,6/6 kV, 6/10 kV, 12/20 kV, 18/30kV – Single Core
                                = AL/XLPE/CWS/SWA/PVC 3,6/6 kV, 6/10 kV, 12/20 kV, 18/30kV – 3 Core
NFA2XSY              = AL/XLPE/CTS/PVC 3,6/6 kV, 6/10 kV, 12/20 kV, 18/30kV – 3 Core
NFA2XSY – T       = AL/XLPE/CTS/PVC + AAAC 3,6/6 kV, 6/10 kV, 12/20 kV, 18/30kV – 3 Core


Tegangan Rendah


Low Voltage Alumunium Non Armour

Low Voltage Tembaga Non Armour
NYA         = Cu/PVC kisaran 450/750 Volt – Single Core
NYF         = Cu-Flex/PVC 450/750 Volt – Single Core
NYM       = Cu/PVC/PVC 300/500 Volt – Multi Core
NYMHY = Cu-Flex/PVC/PVC 300/500 Volt – Multi Core
NYY        = Cu/PVC/PVC 0.6/1 kV – Single Core & Multi Core
NYYHY  = Cu-Flex/PVC/PVC 0.6/1 kV - Single Core & Multi Core
N2XY     = Cu/XLPE/PVC 0.6/1 kV – Single Core & Multi Core
                = Cu-Flex/XLPE/PVC 0.6/1 kV – Single Core & Multi Core


Low Voltage Alumunium Non Armour
NAYA                       = AL/PVC kisaran 450/750 Volt – Single Core
NAYY                       = AL/PVC/PVC 0.6/1 kV – Single Core & Multi Core
NA2XY                     = AL/XLPE/PVC 0.6/1 kV – Single Core & Multi Core
          
Low Voltage Tembaga  Armour
NYRGBY               = Cu/PVC/AWA/PVC 0.6/1 kV – Single Core
                                = Cu/PVC/SWA/PVC 0.6/1 kV – Multi Core
N2XRGBY             = Cu/XLPE/AWA/PVC 0.6/1 kV – Single Core
                                = Cu/XLPE/SWA/PVC 0.6/1 kV – Multi Core
NYFGBY                = Cu/PVC/SFA/PVC 0.6/1 kV – Multi Core
N2XFGBY             = Cu/XLPE/SFA/PVC 0.6/1 kV – Multi Core
 NYBY                    = Cu/PVC/DSTA/PVC 0.6/1 kV – Multi Core    
N2XBY                   = Cu/XLPE/DSTA/PVC 0.6/1 kV – Multi Core    
Low Voltage Alumunium Armour
NAYRGBY            = AL/PVC/AWA/PVC 0.6/1 kV – Single Core
                                = AL/PVC/SWA/PVC 0.6/1 kV – Multi Core
NA2XRGBY          = AL/XLPE/AWA/PVC 0.6/1 kV – Single Core
                                = AL/XLPE/SWA/PVC 0.6/1 kV – Multi Core
NAYFGBY             = AL/PVC/SFA/PVC 0.6/1 kV – Multi Core
NA2XFGBY          = AL/XLPE/SFA/PVC 0.6/1 kV – Multi Core
 NABY                    = AL/PVC/DSTA/PVC 0.6/1 kV – Multi Core    
NA2XBY                = AL/XLPE/DSTA/PVC 0.6/1 kV – Multi Core    

Tambahan
Control Cable with Screening Armour & Non Armour
NYSY = Cu/PVC/CTS/PVC 0.6/1 kV – Single Core & Multi Core
NYCY = Cu/PVC/CWS/PVC 0.6/1 kV – Single Core & Multi Core
N2XSY = Cu/XLPE/CTS/PVC 0.6/1 kV – Single Core & Multi Core
N2XCY = Cu/XLPE/CWS/PVC 0.6/1 kV – Single Core & Multi Core

Twisted Cable – Over Head Cable
TC AL-XLPE  2 x 10 mm- 0.6/1
TC AL-XLPE  2 x 16 mm- 0.6/1
TC AL-XLPE  2 x 25 mm2  - 0.6/1
TC. AL-XLPE 4 x 16 mm2 - 0.6/1
TC. AL-XLPE 4 x 25 mm2 - 0.6/1
TC. AL-XLPE 4 x 35 mm²  - 0.6/1

Twisted Cable dengan penggantung
TC. AL-XLPE 2 x 25 + 1 x 25 mm
TC. AL-XLPE 2 x 35 + 1 x 25 mm
TC. AL-XLPE 2 x 50 + 1 x 35 mm
TC. AL-XLPE 2 x 70 + 1 x 50 mm
TC. AL-XLPE 2 x 95 + 1 x 70 mm
TC. AL-XLPE 3 x 25 + 25 mm2
TC. AL-XLPE 3 x 35 + 1 x 25 mm
TC. AL-XLPE 3 x 50 + 1 x 35 mm
TC. AL-XLPE 3 x 70 + 1 x 50 mm
TC. AL-XLPE 3 x 95 + 1 x 70 mm


Naldz Harry Hatake

Author :

Anda Baru Saja Membaca Artikel Tentang Kabel Kabel yang Digunakan Ditegangan Rendah(TR),Menengah(TM) dan Tinggi(TT) ,Anda Boleh Menyebarluaskan / Mengcopy Paste Artikel Kabel Kabel yang Digunakan Ditegangan Rendah(TR),Menengah(TM) dan Tinggi(TT) Ini Jika Bermanfaat Buat Anda , Namun Saya Mohon Untuk Mencantumkan Link Kabel Kabel yang Digunakan Ditegangan Rendah(TR),Menengah(TM) dan Tinggi(TT) Sebagai SumberNya Dan jangan Lupa Berikan Komentarnya. Terimakasih atas kunjungannya kalian baru saja membaca artikel berjudul Kabel Kabel yang Digunakan Ditegangan Rendah(TR),Menengah(TM) dan Tinggi(TT)
.
Share Artikel

Artikel Terkait

1 comments:

The information is very useful and useful, awaited your next article

Bandarq Online
Agen poker online
Agen poker terbaik

-----------GUNAKAN GOOGLE CROME UNTUK TAMPILAN MAKSIMAL BLOG INI-----------

Berikan Comentarnya ya Gan, :)
--Berkomentarlah yang Relevan
--Berkomentar dengan bahasa yang baik dan benar
--Dilarang membuat rusuh [-(
--Dilarang meletakan LINK aktif [-(
--Dilarang meletakan link porno/iklan [-(
--Boleh meletakan Link non aktif selama tidak menyalahi aturan :-)
--Jika ingin dikunjung/komentar balik(yang sebelumnya belum ada perjanjian) harap sertakan link non aktif

---Terimakasih Telah Berkunjung Dan Komentarnya

“Selamat Datang DiBlog Naldo Hatake”
Saya Naldz Harry Hatake selaku Admin disini mengucapkan TerimaKasih Kepada agan Yang telah berkunjung keblog Sederhana Ini, "Semoga Pada Artikel yang akan Agan baca dan simak bisa bermanfaat untuk agan", "Pastikan anda menggunakan GOOGLE CROME agar tampilan tidak kacau"
"Jangan lupa berikan comentarnya YA :)"

Lanjutkan →